دوره 6، شماره 4 - ( 1395 )                   جلد 6 شماره 4 صفحات 14-1 | برگشت به فهرست نسخه ها

XML English Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Karia B M, Heidari S, Abravesh M. Thermal Performance Evaluation of Low-E Coated Building Glazing Systems. Naqshejahan 2017; 6 (4) :1-14
URL: http://bsnt.modares.ac.ir/article-2-3463-fa.html
Karia Behrouz Mohammad، Heidari Shahin، Abravesh Mahdieh. Thermal Performance Evaluation of Low-E Coated Building Glazing Systems. نقش جهان - مطالعات نظری و فناوری های نوین معماری و شهرسازی. 1395; 6 (4) :1-14

URL: http://bsnt.modares.ac.ir/article-2-3463-fa.html


1- Department of Energy, Road, Housing & Urban Research Center, Tehran 1463917151, Iran
2- Faculty of Architecture, College of Fine Arts, University of Tehran, Tehran 14395-1561, Iran
چکیده:   (8645 مشاهده)
Considering the determinant role of energy efficiency opportunities in the building sector, proposing guidelines and technical solutions in order to improve the thermal performance of glazing systems is in priority in Iran and other countries. In glazing systems, a substantial amount of radiative heat transfer results from absorption and emission. Applying low-E (low emissivity) coatings on the glazing system is a solution for reducing the radiative heat transfer by radiation in glazing systems, without a noticeable decrease of visible light transmittance. By selecting the proper glazing type, in a hot climate, the amount of solar heat gain can be reduced significantly. Vice versa, in cold climate, the heat loss by long wave radiation of inner surfaces can be reduced. In this paper, first, the thermal and optical characteristics of local clear and Low-E glasses have been measured in BHRC (Road, Housing & Urban Development (National) Research Center) laboratory, by the spectrophotometer and then the thermal performance of single and double glazing units, with and without low-E coating, in different orientations (North, South, East and West) are computed, compared and analyzed for cold (Ardebil) and hot (Bandar-Abbas) climates in Iran. The selection of these two cities is based on maximum heating and cooling degree day values obtained respectively for Ardebil and Bandar-Abbas. The simulation results indicate that using double clear glazing unit with low-E coating reduces the energy consumption significantly in very hot climates, using mostly electrical energy for cooling. In cold climates like Ardebil, double glazing with low-E coating has a minor impact on annual heating load, because of the great amount of thermal radiation, even in the cold season, the high cost of low-e coating and the considerable payback time, compared to the building life cycle.
متن کامل [PDF 1190 kb]   (5241 دریافت)    

دریافت: 1396/2/2 | پذیرش: 1395/10/12 | انتشار: 1396/2/2

ارسال نظر درباره این مقاله : نام کاربری یا پست الکترونیک شما:
CAPTCHA

بازنشر اطلاعات
Creative Commons License این مقاله تحت شرایط Creative Commons Attribution-NonCommercial 4.0 International License قابل بازنشر است.