<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE ArticleSet PUBLIC "-//NLM//DTD PubMed 2.7//EN" "https://dtd.nlm.nih.gov/ncbi/pubmed/in/PubMed.dtd">
<ArticleSet>
<Article>
<Journal>
				<PublisherName>دانشگاه تربیت مدرس</PublisherName>
				<JournalTitle>نقش جهان - مطالعات نظری و فناوری های نوین معماری و شهرسازی</JournalTitle>
				<Issn>2322-4991</Issn>
				<Volume>14</Volume>
				<Issue>4</Issue>
				<PubDate PubStatus="epublish">
					<Year>2025</Year>
					<Month>01</Month>
					<Day>20</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Comparative Investigation of Thermal Performance of Multi-Layered Canopies with Complex Geometries in Double-Skin Facades</ArticleTitle>
<VernacularTitle>بررسی تطبیقی عملکرد حرارتی سایبان‌های چندلایه با هندسه‌های پیچیده در نمای دو پوسته</VernacularTitle>
			<FirstPage>125</FirstPage>
			<LastPage>156</LastPage>
			<ELocationID EIdType="pii">1011</ELocationID>
			
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>مصطفی</FirstName>
					<LastName>حسینی واجاری</LastName>
<Affiliation>دانشجوی دکتری معماری، واحد سمنان، دانشگاه آزاد اسلامی، سمنان، ایران</Affiliation>

</Author>
<Author>
					<FirstName>حسین</FirstName>
					<LastName>مرادی نسب</LastName>
<Affiliation>دانشیار گروه معماری، واحد سمنان، دانشگاه آزاد اسلامی، سمنان، ایران</Affiliation>
<Identifier Source="ORCID">0000-0002-5521-5848</Identifier>

</Author>
<Author>
					<FirstName>مرتضی</FirstName>
					<LastName>بهزادنسب</LastName>
<Affiliation>گروه  مهندسی پلیمر، گروه رنگ، پژوهشکده فرایند پلیمرها، پژوهشگاه پلیمر و پتروشیمی ایران، تهران، ایران</Affiliation>

</Author>
<Author>
					<FirstName>محمود</FirstName>
					<LastName>نیکخواه شهمیرزادی</LastName>
<Affiliation>گروه مهندسی عمران، واحد سمنان، دانشگاه آزاد اسلامی، سمنان، ایران</Affiliation>

</Author>
<Author>
					<FirstName>مجید</FirstName>
					<LastName>سلطانی</LastName>
<Affiliation>استادیار دانشکده مهندسی مکانیک، دانشگاه صنعتی خواجه نصیرالدین طوسی، تهران، ایران</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
		<Abstract>&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;Aims:&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt; This study aims to investigate the impact of shading devices and airflow velocity on the thermal (energy) performance and convective flow in a south-facing double-skin façade of a building located in Semnan, a hot and arid region in Iran. The research seeks to determine which type of shading device, including inclined and multi-layer shades, can most effectively reduce indoor temperature and enhance convective flow.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;Methods:&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt; Numerical simulations were conducted using SolidWorks and COMSOL Multiphysics software for geometry modeling, fluid flow simulation, and heat transfer analysis, respectively. A two-dimensional double-skin façade with various shading configurations was considered, and turbulent natural ventilation flow within them was examined.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;Findings:&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt; Simulation results demonstrated that the geometry and airflow velocity significantly influenced the velocity and turbulence of the airflow within the double-skin cavity. A geometry with a multi-layer (asymmetric) shading device exhibited an 18.5% temperature reduction at the same wind speed. The maximum temperature reduction occurred in a geometry with a multi-layer (asymmetric) shading device and an airflow velocity of 5 meters per second. In other words, the best thermal performance was observed in multi-layer shading devices.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;Conclusion:&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt; This research indicated that the use of multi-layer (asymmetric) shading devices can effectively reduce indoor temperature and enhance convective flow. These findings suggest that the appropriate design of shading devices can be employed as a passive method to reduce energy consumption in buildings.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;RTL&quot;&gt;&lt;span&gt;&lt;span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;</Abstract>
			<OtherAbstract Language="FA">&lt;span&gt;اهداف&lt;/span&gt;&lt;span&gt;: بررسی تأثیر سایبان و سرعت جریان هوا بر عملکرد حرارتی (انرژی) و&lt;/span&gt; &lt;span&gt;جریان همرفت در نمای دوپوسته جنوبی یک ساختمان واقع در شهر سمنان&lt;/span&gt; &lt;span&gt;در منطقه گرم خشک ایران. این تحقیق به بررسی کدام نوع سایبان، از جمله سایبان‌های مورب و چندلایه، می‌تواند به طور&lt;/span&gt; &lt;span&gt;مؤثرتری دمای داخل ساختمان را کاهش داده و جریان همرفت را افزایش دهد.&lt;/span&gt;&lt;br&gt;
&lt;span&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;br&gt;
&lt;span&gt;روش ها:&lt;/span&gt;&lt;span&gt; از شبیه‌سازی عددی با استفاده از نرم‌افزارهای سالیدورک و&lt;/span&gt; &lt;span&gt;کامسول مولتی‌فیزیک به ترتیب برای مدل‌سازی هندسه، شبیه‌سازی جریان سیال و انتقال حرارت استفاده شده است. یک نمای دوپوسته دو بعدی با سایبان‌های مختلف در نظر&lt;/span&gt; &lt;span&gt;گرفته شده و جریان تهویه طبیعی آشفته در آنها بررسی شده است.&lt;/span&gt;&lt;br&gt;
&lt;span&gt;یافته­ ها:&lt;/span&gt; &lt;span&gt;نتایج بدست آمده از شبیه‌سازی نشان داد که هندسه و سرعت جریان هوا بر سرعت و آشفتگی جریان هوا&lt;/span&gt; &lt;span&gt;در داخل حفره پاکت دوپوسته تأثیرگذار است. هندسه‌ای با سایبان چند&lt;/span&gt;&lt;span&gt;لایه (غیرمتقارن)، 5/18 درصد کاهش دما را در همین سرعت باد نشان داد. بیشترین کاهش دما در هندسه‌ای با سایبان چندلایه (غیرمتقارن) و سرعت جریان هوای ۵&lt;/span&gt; &lt;span&gt;متر بر ثانیه رخ داده است. به عبارتی، بهترین عملکرد حرارتی در سایبانهای چند لایه مشاهده شده&lt;/span&gt; &lt;span&gt;است.&lt;/span&gt; &lt;br&gt;
&lt;span&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;br&gt;
&lt;span&gt;نتیجه ­گیری:&lt;/span&gt;&lt;span&gt; این پژوهش نشان داد که استفاده از سایبان‌های چندلایه (غیرمتقارن) می‌تواند به طور مؤثری&lt;/span&gt; &lt;span&gt;دمای داخل ساختمان را کاهش داده و جریان همرفت را افزایش دهد. این یافته‌ها حاکی از آن است که&lt;/span&gt; &lt;span&gt;طراحی مناسب سایبان‌ها می‌تواند به عنوان یک روش غیر فعال برای کاهش مصرف انرژی در&lt;/span&gt; &lt;span&gt;ساختمان‌ها مورد استفاده قرار گیرد.&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;br&gt;</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">نمای دوپوسته</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">سایبان</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">جریان همرفت</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">جریان آشفته</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">آسایش حرارتی</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">فناوری های نوین معماری</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://bsnt.modares.ac.ir/article_1011_7f975a56c761db6506eca0b37ce6ec87.pdf</ArchiveCopySource>
</Article>
</ArticleSet>
