<ArticleTitle>Analysis of Performance of Three Wind-catchers for Ventilation of Contemporary Houses in Isfahan- Hot and Arid Climate  - hot and dry climate of Isfahan</ArticleTitle>
<VernacularTitle>Analysis of Performance of Three Wind-catchers for Ventilation of Contemporary Houses in Isfahan- Hot and Arid Climate  - hot and dry climate of Isfahan</VernacularTitle>
			<FirstPage>16</FirstPage>
			<LastPage>32</LastPage>
			<ELocationID EIdType="pii">916</ELocationID>
			
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>Asma</FirstName>
					<LastName>Hojati</LastName>
<Affiliation>Faculty of Architecture &amp; Urban Design, Art University of Isfahan, Isfahan, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Mahdi</FirstName>
					<LastName>Saedvandi</LastName>
<Affiliation>Faculty of Architecture &amp; Urban Design, Art University of Isfahan, Isfahan, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Enrico</FirstName>
					<LastName>De Angelis</LastName>
<Affiliation>Enrico De Angelis, Department of Architecture, Construction Engineering and Built Environment, Politecnico di Milano, Milan, Italy</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
		    <Abstract>Aims: Wind Catchers, as a traditional method of cooling, are compatible with the environment, on the one hand, and reduce energy consumption which is a major global challenge, on the other hand. This study evaluates the thermal and ventilation performance inside different floors of a four-story residential building by using three one-sided, two-sided, four-sided wind catcher models in hot and dry weather in open window mode.
Methods: The analysis by computer modeling or computational fluid dynamics (CFD) to evaluate the cooling potential and flow rate during the summer solstice
Finding: The results show that one-sided wind catchers are not efficient due to the low average inlet air and the negative airflow in the central shaft. Two-sided wind catchers have a positive airflow rate in the warm months, but a four-story building, cannot have the amount of air needed for ventilation on the first and second floors. Among three samples, the simulated four-sided Wind Catchers model has higher refrigeration power and optimal efficiency because it can provide airflow with appropriate speed and volume for the first to fourth floors
Conclusion: Among the three wind catcher modeled in software, it has been determined that only the four-way model can have the necessary efficiency to perform ventilation in different floors. designers can design an optimized design and a building that is more compatible with natural ventilation to provide comfort for residents, according to some special points for the use of wind catchers.</Abstract>
			<OtherAbstract Language="FA">Aims: Wind Catchers, as a traditional method of cooling, are compatible with the environment, on the one hand, and reduce energy consumption which is a major global challenge, on the other hand. This study evaluates the thermal and ventilation performance inside different floors of a four-story residential building by using three one-sided, two-sided, four-sided wind catcher models in hot and dry weather in open window mode.
Methods: The analysis by computer modeling or computational fluid dynamics (CFD) to evaluate the cooling potential and flow rate during the summer solstice
Finding: The results show that one-sided wind catchers are not efficient due to the low average inlet air and the negative airflow in the central shaft. Two-sided wind catchers have a positive airflow rate in the warm months, but a four-story building, cannot have the amount of air needed for ventilation on the first and second floors. Among three samples, the simulated four-sided Wind Catchers model has higher refrigeration power and optimal efficiency because it can provide airflow with appropriate speed and volume for the first to fourth floors
Conclusion: Among the three wind catcher modeled in software, it has been determined that only the four-way model can have the necessary efficiency to perform ventilation in different floors. designers can design an optimized design and a building that is more compatible with natural ventilation to provide comfort for residents, according to some special points for the use of wind catchers.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">windcatcher</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">natural ventilation</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Energy efficiency</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">contemporary architecture</Param>