Optimal Placement of Shadow Tools of Double-skin Facade with the Aim of Achieving Thermal Comfort in Hot Climate

Document Type : Analytic Review

Authors
1 Architecture Department, Semnan Science & Research Branch, Islamic Azad University, Semnan, Iran
2 Architecture Department, Technical Faculty, North Tehran Branch, Islamic Azad University, Tehran, Iran
3 Energy & Sustainable Development Research Center, Semnan Branch, Islamic Azad University, Semnan, Iran
Abstract
During the energy crisis and the world’s attention to optimal energy consumption, especially in buildings, the walls of the buildings became one of the most important parts of the design process. In the first step, air locking and isolation of the walls were important in order to prevent the loss of energy. In the next steps, the need to get proper solar radiation in cold areas and the existence of a tool to prevent the entry of solar radiation in hot areas was raised. The aim of this paper is to investigate the effect of the shading tool location and the optimal combination of glass layers in double skin facade in the warm and humid climate of Iran. The methodology for achieving this goal is to use computer simulations (Fluent software). In this study, different configurations of double skin facade have been investigated. During these surveys, the structure has been considered optimally in the Kish Climate Zone. Three different areas were investigated for the establishment of shaders; the findings of this study are presented as temperature and air flow diagrams and contours. The results of this research show that the most suitable place for the establishment of the shadow tool is the interior and back of the double skin façade. It was also found that the proper type of double skin facade, in order to prevent the optimum from increasing the internal temperature, includes a glass layer in the outer shell and a window with a double-glazed glass in the inner shell. In this paper, the “simulation and modeling research” method has been used. In this paper, the “simulation and modeling research” method has been used. In the software simulation and numerical analysis sections, the type of quantitative research is “analytic” research method and results are obtained based on “induction”.

Keywords

Subjects


Mohammadi M, Heidari Sh. Air flow window an effective element in reduction of buildings' energy consumption in Tehran. Honar-Ha-Ye-Ziba. 2015;20(2):13-22. [Persian]
Saghafi MJ, Tavassoli N. The effect of the ventilated air layer in the new open joint facade on energy performance of the building. Naqshe-Jahan. 2016;6(3):5-14. [Persian]
Afshinmehr V, Aref F, Shanehsaz M. A numerical analysis of double skin facades in summer. Naqshe-Jahan. 2015;5(2):77-85. [Persian]
Hensen J, Bartak M, Drkal F. Modeling and simulation of a double-skin façade system. ASHRAE Trans. 2002;108(2):1251-9.
Ding W, Hasemi Y, Yamada T. Natural ventilation performance of a double skin facade with a solar chimney. Energy Build. 2005;37(4):411-8.
Mahmoodi M, Nivi S. The process of climate technology development with a sustainable development approach. Naqshe-Jahan. 2011;1(1):35-52. [Persian]
Gratia E, De Herde A. Natural cooling strategies efficiency in an office building with a double-skin façade. Energy Build. 2004;36(11):1139-52.
Hashemi N, Fayaz R, Sarshar M. Termal behavior of a ventilated double skin facade in hot arid climate. Energy Build. 2010;42(10):1823-32.
Gratia E, De Herde A. Greenhouse effect in double-skin facade. Energy Build. 2007;39(2):199-211.
Jiru TE, Haghighat F. Modeling ventilated double skin façade-A zonal approach. Energy Build. 2008;40(8):1567-76.
Baldinelli G. Double skin façades for warm climate regions: Analysis of a solution with an integrated movable shading system. Build Environ. 2009;44(6):1107-18.
Mulyadi R, Yoon G, Okumiya M. Study on solar heat gain and thermal transmittance of east and west facing double skin façade in hot and humid climate. AIJ J Technol Des. 2012;18(40):989-94.
Ghanbaran A, Hosseinpour MA. Assessment of design parameter influence on energy efficiency in educational buildings in Tehran’s climate. Naqshe-Jahan. 2016;6(3):51-62. [Persian]