Saghafi M, Fakhari M. The Effect of solar chimney on building ventilation in different climate of Iran. Naqshejahan. 2012;2(2):43-54. [Persian]
Mohammad Moradi A, Hosseini SB, Yazdani H. Controlling enviromental impact of building through assessment and imprrovement of constructed embodied energy. Naqshejahan. 2012;2(2):55-66. [Persian]
Mahdavinejad MJ, javanrodi K. Comparative evaluation of airflow in two kinds of Yazdi and Kermani wind-towers, Honarhaye Ziba (Memari va Shahrsazi). 2012;3(4):69-79.
Mahdavinejad MJ, Bemanian MR, Matoor S. Estimation performance of horizontal light pipes in deep-plan buildings, case study: Tehran Office building. Honarhaye Ziba (Memari va Shahrsazi). 2013;17(4):41-8. [Persian]
Mahdavinejad M, Setayesh Nazar N. Daylighting High-performance architecture: Multi-objective optimization of energy efficiency and daylight availability in BSk cimate, J Energy Procedia. 2017;115:92-101.
Heidari F, Mahdavinejad M, Sotodeh SH. Renewable energy and smart hybird strategies for high performance architecture and planning in case of Tehran, Iran. IOP Conf Ser Earth Environ Sci. 2018;159:1-10.
Habib F, Barzegar Z, Cheshmeh Ghasabani M. Prioritization of Effective Building Energy Consumer Parameters by AHP. Naqshejahan. 2014;4(2):55-61.
Seppänen OA, Fisk W. Some quantitative relations between indoor environmental quality and work performance or health. HVAC&R Res. 2006;12(4):957-73.
Erdmann CA, Steiner KC, Apte MG. Indoor carbon dioxide concentrations and sick building syndrome symptoms in the base study revisited: Analyses of the 100 building dataset. Berkeley: Lawrence Berkeley National Laborator; 2002.
Apte MG, Fisk WJ, Daisey JM. Indoor carbon dioxide concentrations and SBS in office workers. Proc Healthy Build Expos hum responses build investig . 2000;1:133-8.
Kosonen R, Tan F. The effect of perceived indoor air quality on productivity loss. Energy Build. 2004;36(10):981-6.
Afshinmehr V, Aref F, Shaneh Saz M. A numerical analysis of double skin facades in summer. Naqshejahan. 2015;5(2):77-85. [Persian]
Abasi MR, Tahbaz M, Vahabi R. Introducing an innovative variable building layers system (V.B.L.S). Naghshejahan. 2015;5(2):43-54.
Prill R. Why measure carbon dioxide inside buildings. Washington: Washington State University Extension Energy Program; 2000. pp. WSUEEP07-003.
ASHRAE 62.2-2007. ventilation for acceptable indoor air quality in low-rise residential buildings. Atlanta: American Society of Heating, Refrigerating and AirConditioning Engineers; 2007.
Parameshwaran R, Kalaiselvam S, Harikrishnan S, Elayaperumal A. Sustainable thermal energy storage technologies for buildings: A review. Renew Sustain Energy Rev. 2012;16(5):2394-433.
Turiel I, Hollowell CD, Miksch RR, Rudy JV, Young RA, Coye MJ. The effects of reduced ventilation on indoor air quality in an office building. Atmos Environ. 1983;17(1):51-64.
Swift Jr. Lawrence T, editors. ASHRAE Green Guide: The design, construction, and operation of sustainable building. 3rd Edition. Atlanta: American Society of Heating, Refrigerating and Air-Conditioning Engineers; 2010.
Persily AK. Evaluating building IAQ and ventilation with indoor carbon dioxide. Am Soc Heat Refrig Air Cond Eng. 1997;103:193-204.
Charles KE, Magee RJ, Won D, Lusztyk E. Indoor air quality guidelines and standards. Natl Res Counc Can. 2005; p. B3312.
Ansarimanesh M, Nasrollahi N. Determination of occupants thermal zone to maximize the quality of indoor environment in office building of Kermanshah. Naghshejahan. 2014;4(2):17-27. [Persian]
ASHRAE 55-2013. Thermal Environmental Conditions for Human Occupancy (ANSI Approved). Atlanta: American Society of Heating, Refrigerating and Air-Conditioning Engineers; 2013.