Integrating Thermal and Lighting Analysis to Optimize Window Size of Educational Buildings

نویسندگان
1 Assistant Professor, Building Physics, Building and Housing Research Center, Tehran, Iran
2 Associate Professor (Corresponding Author), Department of Architecture and Urbanism, University of Art, Karaj, Iran
3 M.Sc. Student, Sustainable Architecture, University of Art, Karaj, Iran
چکیده
Designing buildings with the lowest possible cost base is an essentiality in sustainable architecture. Previously, due to the computational complexity of building's energy consumption, the environmental impact on thermal and lighting energy consumptions haven't been considered simultaneously. As non-linear relationships are often disclosed, a comprehensive approach is necessary to reduce the total energy need of a building and optimize the façade configuration at the same time. Solar radiation affects thermal and lighting energy consumption which depends on building fabric’s characteristics. In this paper a parametric method to optimize the window size and sunshade dimensions of an educational building in mild climate of Iran is presented. Through integrating thermal and lighting energy consumption, 6750 window and sunshade configurations are studied and compared. First, climatic parameters and thermal analysis are validated by on-site measurements. Then, the characteristics of the simulated model and all thermal and lighting parameters have been defined. Finally, the best solution is optimized through genetic algorithm. The results show that, in the first phases of the design process building’s characteristics should comply with national code regulations and then components of the building will be optimized. Additionally the horizontal windows with higher sill levels are more energy-efficient in classrooms.

[1]. Raphaela W.Development of a daylighting index for window energy labelling and rating system for residential buildings in brazil, In:Proceedings of BS2013: 13th Conference of International Building Performance Simulation Association, Chambery, France, 2013.
[2]. Mardaljevic J, Andersen M, Roy N. Daylighting Metrics for Residential Buildings. In: Proceedings of the 27th Session of the CTE, Sun City, South Africa, July ll-l5. Christoffersen, J. 20ll.
[3]. Grynninga S, Gustavsena A, Time B, Jelle BP. Windows in the buildings of tomorrow: Energy losers or energy gainers?.Energy and Buildings 2013; 61: 185–192.
[4]. EN 15603: Energy performance of buildings – overall energy use and definition of energy ratings.
[5]. Goia F, Haase M, Perino M. Optimizing the configuration of a façade module for office buildings by means of integrated thermal and lighting simulations in a total energy perspective. Applied Energy 2013; 108: 515–527.
[6] IES Lighting Handbook-Window design, P50[7] Kamila ML, Rosana MC. The influence of window-related design variables on thermal, daylight and energy performance of offices. In: Proceedings of the Building simulation and optimization 2014; 22, < http://www.bso14.org/BSO14_Papers/BSO14_Paper_022.pdf>.
[8]. Shen H, Tzempelikos A. Sensitivity analysis on daylighting and energy performance of perimeter offices with automated shading. Building and environment 2013;59: 303-314.
[9]. Melendo JMA, Roche P. Effects of window size in daylighting and energy performance in buildings, In: Proceedings of the PLEA 2009, 26th Conference on Passive and Low Energy Architecture, Quebec City, Canada, June 2009, .
[10]. Francisco A. Day Lighting as a Factor in Optimizing the Energy Performance of Buildings.Energy and Building1977; 1: 175-182.
[11] Lyons P and associates. Report to Australian Building Codes Board on Optimum Window Size for Energy Efficiency. BCA 2008;1.
[12]. Hassouneh K, Alshbou A, Salaymeh AAl. Influence of windows on the energy balance of apartment buildings in Amman. Energy Conversion and Management 2010;51: 1583-1591.
[13]. Stavrakakis GM, Karadimou DP, Zervas PL, Sarrimveis H, Markatos NC. Selection of window sizes for optimizing occupational comfort and hygiene based on computational fluid dynamics and neural networks. Building and environment 2011;46: 298-314.
[14]. Ochoa CE, Aries MBC, Loenen EJ, Hensen JLM. Considerations on design optimization criteria for windows providing low energy consumption and high visual comfort. Applied Energy 2012; 95: 238–245.
[15]. Dussaul J, Gosseli L, Galstian T. Integration of smart windows into building design for reduction of yearly overall energy consumption and peak loads. Solar Energy 2012; 86: 3405–3416.
[16]. Mari LP, Arne R, Maria W. Influence of window size on the energy balance of low energy houses. Energy and Building 2006;38: 181-188.
[17]. Lee ES, Dibartolomeo DL, Selkowitz SE. Thermal and daylighting performance of an automated venetian blind and lighting system in a full-scale private office. Energy and Building 1998;29 :47-63.
[18].Shikder SH, Mourshed M, Price ADF. Optimization of a daylight-window: Hospital patient room as a test case. In: Proceedings of the international conference on computing in civil and building engineering, Nottingham University Press, 2010.
[19].Ayda MK, Superviser: Rima F, Adviser: Mohammad BK. Master thesis, University of Art, Energy and Architecture. Optimizing window size regarding heat gains and light in residential buildings of moderate and humid climatic zone. J 2015.
[20].Energyplus engineering reference, , October 2011.
[21]. DAYSIM is validated: RADIANCE-based day-lighting analysis software that models the annual amount of daylight in and around buildings, .
[22]. RADIANCE, the Radiance 4.0 Synthetic Imaging System, Lawrence Berkeley, National Laboratory, 2010.
[23]. Mardaljevic J, Nabil A. The useful daylight illuminance paradigm: A replacement for daylight factors. Lux Europa, Berlin 2005: 169–174.
[24]. ANSI/ASHRAE/IESNA Standard 90.1 Normative Appendix B–Building Envelope Climate Criteria. The information below is from Tables B-2, B-3, and B-4, 2007.
[25]. National building code, part 19, saving energy, Iran Building and Housing Research Center, 1389.
[26]. National building code, part 13, Design and implementation of electrical installations for buildings, Iran Building and Housing Research Center, 1388.